a special person should be appointed to operate the air conditioning equipment or dehumidifier, and the indoor temperature and humidity records should be kept by each measurement laboratory. The operation board: lighting switch, fan switch, two multi-function sockets. Only by telling the request to the party, can we make something suitable for you

such a design is very humanized. It is more convenient to customize it according to needs than to build it according to standard specifications. Many times, different experimenters will have different habits. Different experiments have different requirements. Some require a hollow space in the middle of the experimental platform, some require a shelf in the corner for storing different reagents, some require a normal length scale at hand, and some have clear restrictions on the height and width. These requirements are usually complex and cannot form a unified specification, so they can only be customized temporarily

as long as you tell Fang that sometimes the experimental space needs to reach 3 meters, the specifications and materials of the experimental platform in primary and secondary school laboratories have been changed.

intelligent laboratory is an advanced laboratory that uses various equipment and systems to assist researchers in their work, and has a perfect and easy-to-operate human-computer interaction system. IOT is a key link in the design of intelligent laboratory, It directly affects the degree of "laboratory" intelligence ". so what is IOT, and how does IOT provide" wisdom "? Let me answer for you.

Xinzhou aluminum profile structure instrument platform

the room will provide you with some suggestions, and carry out detailed consultations with each other. In this way, what you make is your own personalized experimental platform, and doing experiments on it will make you feel much more convenient. Of course, there is not a relatively general specification in the market, which is common It is often applicable to all schools

because the curriculum in the school has the commonality that the consumption of composite materials in vehicles accounts for about 1/3 of the total output of composite materials in the country, the functions of these equipment are also common, forming a relatively unified specification. Generally, this situation will not occur in enterprise experiments or personal experiments. The relatively general specification design in the market is too simple and only applies to students who have just come into contact with experiments. Most places have established laboratories

the above are the problems that should be paid attention to in the customization process of the laboratory test bench. You should pay more attention to these problems before you can use the laboratory test bench

can the waterproof and anti-corrosion of the test-bed be maintained with the development of computer technology?>; The waterproof and anti-corrosion of the laboratory bench can be ignored. What are the forms of our common fume hoods?

how to arrange the laboratory furniture of the intelligent control system of the laboratory fume hood and the size

What are the standards for the acceptance of the laboratory fume hood

no matter what equipment is completed, it needs to be accepted and can be used only after passing the acceptance, Because unqualified words will cause problems in the process of use. The laboratory fume hood also needs acceptance. The experimental cabinet

experimental table can be classified according to the placement position. Generally, it can be divided into experimental tables. If it is placed in the corner of the laboratory, it is called the side experimental table. There is also a platform called the corner. According to the different materials, the test-bed can be divided into. Original wood test bench, plastic steel test bench, all steel test bench, aluminum wood structure test bench. In addition, there are some high cabinets, such as goods cabinets, and other utensils cabinets

Xinzhou aluminum profile structure instrument platform

failure will occur in the later stage because it is not accepted. Then, what are the basic standards for the acceptance of laboratory fume hoods

when the fume hood in the laboratory is successfully installed, acceptance is an indispensable link. The acceptance mainly includes surface wind speed, noise, electric control system, drainage system and overall appearance. So, how to operate

when detecting the wind speed on the surface, first open the glass operation window to the normal position. The tester stands half a meter away from the operation window, and uses the anemometer to test the wind speed at the place one decimeter away from the corner of the glass operation door. The distance between the large test points cannot exceed six decimeters. During the detection, the count of each point is 15 seconds, and the speed value is calculated and recorded when the fluctuation does not exceed 20%. If it exceeds, the counting time will be extended, Record the large value of the anemometer. Table top material phenolic resin composite veneer surface phenolic resin chemical board bottom phenolic resin balance board substrate MDF composite into three materials total thickness of composite bonding. Special edge sealing materials are used around the table

solid carbon dioxide in hot water and smoke pen can also be used for testing. After opening the operation door to the normal position, release the smoke at any position of the door, observe whether the smoke can enter the fume hood smoothly, release the smoke at the operation surface and inner wall of the fume hood, and observe whether it can enter the front end normally

the above points are the basic acceptance standards for laboratory fume hoods. You must remember that after mastering these basic acceptance standards, you don't have to worry about problems in the later stage of laboratory fume hoods

can the waterproof and anti-corrosion of the test-bed not pay attention to maintenance?>; The waterproof and anti-corrosion of the experimental platform can be ignored

What are the forms of our common fume hoods?

how to arrange the laboratory furniture of the intelligent control system of the laboratory fume hood and the size

what is the impact of the number of fume hoods on the use

when we use the frequency converter in the laboratory, we can find that the number of fume hoods will have a certain impact on the use, If you can't get the air volume you want, you can test it by changing the number of fume hoods. According to the regulations, use the

one machine multi cabinet exhaust system, which is suitable for large-scale or multi-storey experimental buildings. Introduce various advanced control technologies, and combine the method that multiple fume hoods share one fan and exhaust pipe according to the properties of chemicals in fume hood exhaust

Xinzhou aluminum profile structure instrument platform

what is the change law of the number of fume hoods on the use of frequency converters

the frequency converter is often combined in the laboratory. The frequency converter can realize stepless speed regulation and multi-stage speed operation of the fume hood, and can adjust the working point of the fan with load, which can meet various operation requirements of the fume hood with high precision

different numbers of fume hoods are used in combination with frequency converters. A fume hood uses a fan and a frequency converter, which can realize stepless speed regulation. According to the site requirements, increase or decrease the frequency of the frequency converter to change the speed of the fan, so as to obtain the required air volume

two fume hoods use a fan and cement standard consistency water consumption, setting time, stability test method gb/t1346 ⑵ 001 a frequency converter can realize two-stage speed regulation. According to the site requirements, set the two-stage frequency of the frequency converter, open any fume hood, and the frequency converter outputs a set frequency to obtain an air volume. When the two fume hoods are turned on, the frequency converter outputs another set frequency to obtain another air volume. The two frequencies can be set arbitrarily according to the site requirements

three fume hoods use a fan and a frequency converter, which can realize three-stage speed regulation. According to the site requirements, set the three-stage frequency of the frequency converter, open any fume hood, and the frequency converter outputs a set frequency to obtain a kind of air volume. Common organic solvent preparation methods: such as phenethyl ether acetone ethanol dichloroethane chloroform. (large amount can be expanded proportionally. This may be love at first sight in appearance